TEDIASENS SN-X

Wireless, synchronous Live Measurement Data Transmission with IEPE Connection

TEDIASENS SN-X is a three-channel radio node suitable for connecting sensors supplied by the radio node to IEPE. It can thus be connected to any three sensors (for example for 3D acceleration measurement, pressure measurement, temperature or transmission measurement). The sensors can be connected to the sensor nodes via BNC connectors and can be fed in accordance with IEPE. Similarly, the inputs can be coupled either AC or DC. The input voltage range can be programmed to ± 1V or ± 10V. With a dynamic range of 24 bits and an SNR of – 109.5 dB RMS and a maximum sampling rate of 13 kHz, avoiding cables can solve a multitude of measuring tasks without a great deal of installation work. Applications for SN-X radio nodes are: Wireless synchronous detection of vibration, oscillation, acceleration, speed, pressure, temperature and acoustic signals.

Synchrone Übertragung von Messdaten, Schwingungen, Vibration, per WLAN

TEDIASENS SN-X

Sensor nodes of type SN-X (sensor node) provide 3 BNC sockets for connection of external sensors. The SN-X are identical to SN-I radio nodes, except for:

  • no integrated accelerometers, instead:
  • Connection of 3 external measurement sensors (vibration, pressure, temperature, speed, force, …)
  • External sensors can be connected to sensor nodes via BNC or LEMO connectors
  • External sensors can optionally be fed IEPE compliant
  • Dynamic of 24 bit and SNR of -109.5dB RMS at a maximum sampling rate of 13 kHz

TEDIASENS SN-X-ECO

Same as TEDIASENS (above), however:

  • no synchronous measurement data transmission when using several radio nodes at the same time
Sensor Node with external sensor technology SN-X
Type of Radio Node Sensor node for connection of external sensor technology
Radio Interface WLAN
Monitoring Type Continuously
External Measurement Channels 3 sensor channels per node
Integrated measurement channels None
Integrated sensor technology
Measurement Range Input voltage range ±1 V; ±10 V available
Measurement Accuracy
Sensor connection / interfaces external channels BNC or optionally LEMO; IEPE supply 18 V; 2mA; switchable
Input Coupling AC/DC available
Bandwidth DC/0,4 Hz – 8,6 kHz (-3dB)
AD converter resolution 24bit
Sampling rate / data acquisition max. 13 kHz per channel
SNR 109,5dB RMS broadband
Channel Sampling Simultaneously
Synchronicity 1 µs standard deviation
Data rate per sensor node 1 MBit/s
Sensor nodes per system 1 to 40 (typically: 10)
Range free field 802.11g 138 m isotropic
Power Supply interneral battery / power supply unit optionally
Measurement Period typ. 7-9 h in battery mode
Battery Charge Time Max. 3 h
Operation 1 switch, or via driver software
Display 4 LEDs (wireless or battery mode)
Dimensions 114,1 x 63,5 x 30,0 mm³ (without antenna)
Weigth 270 g (including battery and antenna)
Protection Class IP 54
Storage
Measurement Trigger

Accessories – Wireless Data Transmission Vibration and Oscillation Measurement Systems

Synchronous Measurement Data Transmission

Standard Accessory

Plug-In Power Supply

TDS-PS

The Plug-In Power Supply TDS-PS serves as a charging unit and can be used for all TEDIASENS radio nodes.

Access Point

TDS-AP

The standard access point for the TEDIASENS radio nodes has its power supply via USB. The data communication works via Ethernet network.

Accelerometer

TDS-ACC

 

Single-axis accelerometer with BNC connector for SN-X sensor nodes
Additional Battery

TDS-EAP

The additional battery extends the operating time of the radio nodes by up to 9 hours.
Rugged

TDS-SNX-R

 

The Rugged impact protection protects the SN-X sensor nodes against damage.

Mobile Equipment

System Case

TDS-CASE

The ELOVIS Transport Cases CASE, which is available in different sizes, are ideal for safe storage and transport of sensor components.

Software

PC Software

TDS-GUI

The TDS-GUI configuration and monitoring software is used to operate, display and store TDS measurement values on a PC, laptop or tablet computer.

Wireless Synchronous Data Transmission

drahtlose Datenübertragung

SN-X: Sensor Node External
– Radio node for connection of external sensors (3 IEPE channels)

SN-I: Sensor Node Internal
– Radio node with integrated 3-axis accelerometer

AP: Access Point
– Wireless LAN: 802.11g

PC communication
– ELOVIS GUI: graphical user interface – LabView based

Videos – Wireless Data Transmission Vibration and Osciallation Measurement Systems

Product Video – TediaSens

Video regarding Wireless Data Transmission Vibration and Oscillation Measurement Systems

Synchronous Wireless Measurement Data Transmission

Product Tutorial and Application Overview

Downloads – Wireless, synchronous Live Measurement Data Transmission with IEPE Connection

TEDIASENS SNX – Data Sheet

APLICACIONES

Transferencia de datos de medición síncrona inalámbrica

¿Deben transmitirse los datos de medición de forma inalámbrica y sincrónica? ¿No encuentra un sistema inalámbrico suf...

Medición de vibración y oscilación

En la resolución de problemas, las mediciones de vibración deben llevarse a cabo rápida y fácilmente en diferentes pu...

Registro de datos de monitorización y medición a largo plazo

Los estados del objeto se deben supervisar durante un largo período de tiempo a intervalos regulares, por lo que los ...

EJEMPLOS DE APLICACIÓN

Monitorización inalambrica de maquinas

El servicio de máquinas requiere un equipo de medición confiable, que se puede usar de forma rápida y segura. Con lo...

Medición inalámbrica de vibraciones / oscilaciones en máquinas de papel

Debido a su tamaño y complejidad, las máquinas de papel son un desafío en la resolución de problemas de vibración. Co...

Prueba de impacto y medición de aceleración para cascos

Los cascos para el deporte y tráfico deben cumplir con altos requisitos de seguridad. El punto decisivo es el efecto...

Siempre disponible:
Bernd Engelsdorf

ELOVIS GmbH

Vincenz-Prießnitz-Straße 1
76131 Karlsruhe, Alemania

T +49 721 933823-0
F +49 721 933823-23

engelsdorf@elovis.de

Información requerida*

Contacto